You may find that getting an exact match to the one you have difficult.
Hot water heater gas valve failure.
Water heaters can explode if the pressure is not relieved so if there is water leaking then it means that the pressure in your tank is exceeding the point where it can be relieved.
Because gas is involved problems with gas valves are a major safety concern.
Example tank is a john wood 40 gallo.
If the valve is the cause then a professional will likely need to repair this.
If the pilot isn t the issue then replacing the gas valve should correct the problem.
7 replace gas valve overall failure of the gas valve and will usually require replacement.
Before you can replace your water heater gas valve you need to purchase a new one.
Shutting off the gas.
Check the gas supply ignition insulation of the electrode the thermostat the ground wire of the gas valve and grounding in general.
When you see water that appears to be leaking from the bottom of a gas water heater it could be because of condensation try turning up the thermostat a leaking or loose drain valve or the t p valve draining some water through the overflow pipe due to tank overpressurization.
A stuck valve could release gas into the air without regulation or the valve could cause the unit not to fire up at all.
The gas pilot valve is the piece that supplies fire to the gas.
5 replace gas valve this indicates a sensor failure and the gas control valve must be replaced.
The first thing you need to do is shut off the gas to the hot water tank.
Water dripping from your pressure relief valve is a good sign it means that the valve is working properly and your heater is not overheating.
Here s what you need to know about replacing your water heater s gas control valve.
It could be the gas pilot valve.
How to diagnose and repair a faulty atmospherically vented gas fired water heater.
This is done at the shut off valve that is in the gas line.
If you get this code and have lukewarm water and the pilot is still on try turning up the temperature.
Water heater problems that may be caused by the gas control valve include a faulty hot water heater thermostat faulty gas valve pilot light that won t light and tripped heat limiter.
A bad gas valve in a honeywell appliance such as a water heater or furnace that is powered by natural gas can go bad and affect the performance of the unit.
If the valve is working hot water shouldn t be an issue.
You can easily clean the components align them correctly tighten loose components ensure proper grounding and adequate gas supply.